Auto recognition of IBM or ISO format magnetic DATA record
LED and beep indicate power . read .write. OK.ER
CARTON CONTENTS
YD-606 OR YD626
1. Magnetic stripe encoder, pre-assembled
2. User Manual
3.get power connect cable
4.Test software
5.clean card
STALLATION
Your magnetic stripe encoder is
pre-assembled for easy installation.
YD-600
1. Connect the male DIN 5 of connect cable to the keyboard port for power
2. Connect the female DIN 5 of connect cable to the system keyboard .
3.Connect the female DB9 of YD-600 connector to the connect cable
4. Connect the male DB9 of the connect cable to the communication port .
Notice:
If the pin # 1 of the computer communication port supplies power, the connect cable will not be used to get power from keyboard. Connect the female DB9 of YD-606&yd-626 connector to the computer communication port directly.
FUNCTIONAL TEST
YD-606 OR YD626
To functionally test the YD-600 will require the use of a standard credit
card. Place the credit card at one end of the Magnetic Stripe encoder.
Face the magnetic stripe of the credit card toward the arrow of the MSR.
Move (swipe) the card through the encoder.
The credit card information will appear on the monitor. The information
shown on the screen will vary according to the card used. The information
should look similar to the following by Magnetic reader :
Track 2 ;9437577710640473475?
Track 3 +43623562346655423465?
INTERFACE
YD-606 OR YD-626
The YD-626 can interface with any
standard IBM RS232C interface. The
output connector of the YD-600 is
a DB9 female connector.
DB9F Configuration:
1 DCD 6 NON
2 RXD 7 NON
3 TXD 8 NON
4 NON 9 NON
5 Sig. Gnd.
Default Protocol
Baud Rate – 1200 2400 4800 9600 bps at option
Parity – None odd
Initial- 1 1
Data Bits – 8 7
Stop Bits – 1 1
SPECIFICATIONS
Mechanical:
Weight 1250G
Dimensions 217mmL x 59mmW x 63.5mmH
Case ABS plastic
Environmental:
Operating Temperature 0 to +50 deg C
Storage Temperature -20 to +70 deg C
Relative Humidity 90%, non-condensing
Vibration 40 G’s
Shock 40 G’s
Reading and Writing Performance:
Card feed speed 10 to 120 mm/second
Card feed force 0.6oz, typical
Magnetic head life 1,000,000 passes min.
Read error rate < 1 in 1000 passes
Electrical:
Voltage 5VDC +/- 10% YD626 Voltage 9VDC
Current 150 ma
LED indicator Green - Good read
or ready to read
Red - Bad read
RECORD DENSITY
Track 1 210bpi max 76 characters
Track 2 75bpi max 37 characters
Track 3 210bpi max 104 characters
DIP SWITCH;
This are 8 dip switches at the back of the PCB
sw1 sw2 for band rate
SW1
SW2
BAND RATE
OFF
OFF
OFF
ON
ON
OFF
ON
ON
2.sw3 for parity
SW3
PARITY
ON
NONE
OFF
ODD
3.sw4 sw5 sw6 for DATA standard
NO.
SW4
SW5
SW6
SOW
EOM
CHARACTER
COMMAND
STANDARD 1
ON
ON
ON
BF
F
0-9=
ESC X 1
STANDARD 2
ON
ON
OFF
BA
F
0-9=’
ESC X 2
STANDARD 3
ON
OFF
ON
BA
C
0-9=’
ESC X 3
STANDARD 4
ON
OFF
OFF
B
F
0-9=’:@
ESC X 4
STANDARD 5
OFF
ON
ON
D
F
0-9=#:@
ESC X 5
STANDARD 6
OFF
ON
OFF
B
C
0-9=’:
ESC X 6
4.sw7 for the start position of DATA (mm)
SW7
POSITION
COMMAND
ON
ESC 6
OFF
ESC 7
COMMAND
1 READ COMMAND
COMMAND
FUNCTUION
RESPONES TO COPMPUTER
ESC ]
(1B 5D)
READ THE DATA OF TRACK 2
ESC s DATA OF TRACK 2? FS
(1B 73 DATA OF TRACK 2 3F 1C)
ESC T ]
(1B 54 5D)
READ THE DATA OF TRACK 3
ESC s A DATA OF TRACK 3 ? FS
(1B 73 41 DATA OF TRACK 3 3F 1C)
ESC B ]
(1B 42 5D)
READ THE DATA OF TRACK 2&3
ESC s DATA OF TRACK 2 A
DATA OF TRACK 3 ? FS
(1B 73 DATA OF TRACK 2 41
DATA OF TRACK 3 3F 1C)
NOTICE: if read success then data of card will be transacted to system , else DEL(0X7F) wiil be tansacted to system.
2.WRITE COMMAND
COMMAND
FUNCTION
ESC t DATA OF TRACK 2 TO BE WRITTEN Gs ESC \
(1B 74 DATA OF TRACK 2 TO BE WRITEN 1D 1B 5C)
WRITE THE DATA OF TRACK 2
ESC t A DATA OF TRACK 3 TO BE WRITTEN Gs ESC \
(1B 74 41 DATA OF TRACK 3 TO BE WRITTEN 1D 1B 5C)
WRITE
THE DATA OF TRACK 3
ESC t DATA OF TRACK 2 TO BE WRITTEN A DATA OF TRACK 3 Gs ESC \
(1B 74 DATA OF TRACK 2 TO BE WRITTEN 41 DATA OF TRACK 3 TO BE WRITEN 1D 1B 5C)
WRITE THE DATA OF TRACK 2 &3
3.STATUS RETURN COMMAND
COMMAND
FUNCTION
RESPONES
ESC j
(1B 6A)
RETURN THE STATUS CODE AFTRER READING OR WRITING THE DATA OF TRACK 2
ESC r p/q/r/s/t
(1B 72 70/71)
NOTICE: THE CODE p INDICTES OK, q INDICTES ERROR,r INDICTES no read and write , s INDICTES write track1 failed , t NDICTES write track 2 faled.
Command ESC j can only after read or write command. If no read or write command ,ESC j will be no function.rele-600 will automatic return status code after failure to read or write