Home Random Page


CATEGORIES:

BiologyChemistryConstructionCultureEcologyEconomyElectronicsFinanceGeographyHistoryInformaticsLawMathematicsMechanicsMedicineOtherPedagogyPhilosophyPhysicsPolicyPsychologySociologySportTourism






PUMP_6017_Recipprocating_pumps

_______________________________________________

Question 1:
Identify part E of the illustration of a mechanically actuated diaphragm pump:


A - Suction valve
B - Pump body
C - Diaphragm
D - Piston guide
_______________________________________________
Question 2:
Identify part D of the illustration of a mechanically actuated diaphragm pump:

 


A - Diaphragm
B - Pump body
C - Suction valve

_______________________________________________

Question 3:

Identify part B of the illustration of a mechanically actuated diaphragm pump:

A - Pump body
B - Diaphragm
C - Piston guide
D - Suction valve

_______________________________________________

Question 4:
Identify part A of the illustration of a mechanically actuated diaphragm pump:


A - Diaphragm
B - Eccentric
C - Piston guide
D - Discharge valve

_______________________________________________

Question 5:
The type of reciprocating pump valve used for high pressure clean service is called a:

A - Flat disk valve
B - Ball valve
C - Wing guided valve
D - Stem guided valve
_______________________________________________

Question 6:
The type of reciprocating pump valve suitable for hot and cold water service at lower pressures is called a:
A - Wing guided valve
B - Stem guided valve
C - Ball valve
D - Flat disk valve
_______________________________________________

Question 7:
A triplex double-acting pump will deliver:
A - Six pulses of liquid in one crankshaft revolution
B - Three pulses of liquid in one crankshaft revolution
C - Six pulses of liquid in three crankshaft revolutions
D - One pulse of liquid in three crankshaft revolutions
_______________________________________________

Question 8:
As a pumping unit, the steam-operated injector is:
A - An important auxiliary and necessary on all types of reciprocating pumps
B - Widely used throughout the petroleum industry
C - Very efficient and easy to control
D - Quite inefficient and difficult to control
_______________________________________________

Question 9:
All power pumps should be equipped with:

A - Drainage valves located upstream of the pump
B - Relief valves on the suction end to prevent damage from overpressure
C - Relief valves on the discharge to prevent damage from overpressure
D - A diaphragm to separate the chamber from the liquid being pumped
_______________________________________________

Question 10:
Ball valves are used where free opening of suction and discharge is required.
A - True
B - False
_______________________________________________

Question 11:
The type of reciprocating pump valve used where free opening of the suction and discharge is required is called a:
A - Stem guided valve
B - Flat disk valve
C - Ball valve
D - Wing guided valve
_______________________________________________

Question 12:
The diaphragm pump differs from the piston or plunger-type reciprocating pump in that:
A - It has no moving parts
B - The fluid is in full contact with the reciprocating mechanism
C - It requires no external power source to drive the pump
D - The fluid is completely isolated from the reciprocating mechanism
_______________________________________________



Question 13:
Reciprocating pumps can be used to develop very high pressures and carefully controlled flows because the volume of liquid discharged depends only upon the _____________ and _________ of the pump.
A - driver size, temperature
B - dimensions, speed
C - dimensions, temperature
D - driver size, speed
_______________________________________________

Question 14:
One method of increasing the volume of flow through a single-acting plunger-type pump is to:
A - Reduce the pressure at the discharge of the pump
B - Increase the level of the liquid tank at the suction side of the pump
C - Increase the length of the pump stroke
D - Open the discharge valve wider
_______________________________________________

Question 15:
Diaphragm pumps are well suited for use as controlled volume or metering pumps because:
A - The fluid is in full contact with the reciprocating mechanism
B - Their capacity is static, ensuring consistent volume on every stroke
C - The fluid is completely isolated from the reciprocating mechanism
D - Their capacity can be adjusted by varying the stroke length or the stroke frequency
_______________________________________________

Question 16:
The discharge of a mechanically actuated diaphragm pump is usually limited to about:
A - 350 kPa
B - 2000 kPa
C - 3500 kPa
D - 350 psi
_______________________________________________

Question 17:
A triplex pump will complete one stroke in:
A - 120 degrees
B - 360 degrees
C - 180 degrees
D - 90 degrees
_______________________________________________

Question 18:
In a plunger-type pump, the distance the plunger moves in and out of the cylinder is called the:
A - Length of stroke
B - Compression stroke
C - Stroke of the pump
D - Power stroke
_______________________________________________

Question 19:
In a plunger type pump, the movement of the plunger in one direction is called the:
A - Length of stroke
B - Compression stroke
C - Stroke of the pump
D - Power stroke
_______________________________________________

Question 20:
A reciprocating pumps capacity depends on:
A - changes in the discharge pressure
B - the number of pumping strokes per minute
C - the clearance between the gears and the pump casing
D - None of the above
_______________________________________________

Question 21:
A piston-type duplex pump has two:
A - Discharge strokes per crankshaft revolution
B - Valves at each end of the pump cylinder
C - Pistons
D - Sources of drive power
_______________________________________________

Question 22:
Why should all power pumps be equipped with relief valves on the discharge?
A - to prevent damage from under-pressure
B - to prevent the driver from stalling
C - to prevent damage from overpressure
D - to allow relief from low operating temperatures
_______________________________________________
Question 23:
Generally, the type of valve used in a pump is determined by the properties of the liquid handled.

A - True
B - False


Date: 2016-01-05; view: 712


<== previous page | next page ==>
INST 6011_Introduction of Pneumatic Controllers | C - External gear pump
doclecture.net - lectures - 2014-2024 year. Copyright infringement or personal data (0.007 sec.)