SAFETY INSTRUCTIONS

CAUTION! Be careful with your operations. With a dangerous voltage you can suffer a dangerous electric shock when touching wires!

 

This device has left the factory in perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual.

1. In order to guarantee the product’s life, please don’t put it in the damp places or even the environment over 60degress.

2. Always mount this unit in safe and stable matter.

The qualified professionals are allowed to carry out the lamp installation, operation and maintenance, but they must guarantee to operate in strict accordance with the instructions referred to.

3. Using lamp, the change rate of power voltage should be within±10%, if the voltage is too high, it will shorten the light’s life; if it’s not enough, the lamp will be dark.

4. Please restart it after turning off light for 20 minutes until full-cooling. Frequent switching will reduce the life span of lamps and bulbs; intermittent using will improve the life of bulbs and lamps.

▲ Important:

Damages caused by the disregard of this user manual are not subject to warranty. The dealer will not accept liability for any resulting defects or problems.

 

If the device has been exposed to temperature changes due to environmental changes, do not switch it on immediately. The arising condensation could damage the device. Leave the device switched off until it has reached room temperatures.

This device falls under protection-classⅠ. Therefore it is essential that the device be earthed.

The electric connection must carry out by qualified person.

Make sure that the available voltage is not higher than stated at the end of this manual.

 

Make sure the power cord is never crimped or damaged by sharp edges. If this would be the case, replacement of the cable must be done by an authorized dealer.

 

Always disconnect from the mains, when the device is not in use or before cleaning it. Only handle the power cord by the plug. Never pull out the plug by tugging the power cord.

 

During initial start-up some smoke or smell may arise. This is a normal process and does not necessarily mean that the device is defective, it should decrease gradually.

 

Please don’t project the beam onto combustible substances.

 

If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard.

CAUTION! Never touch the device during operation! The housing may heat up!

 

C CAUTION! N Never look directly into the light source, A As sensitive persons may suffer an epileptic shock.

 

Please be aware that damages caused by manual modifications to be the device are not subject to warranty. Keep away from children and non-professionals.



INSTALLATION INSTRUCTIONS

CAUTION! Only install the lamp with the device unplugged from the mains.

 

CAUTION! The lamp has to be replaced when it is damaged or deformed.

 

Before replacing the lamp let the lamp cool down, because during operation, the lamp can reach very high temperature.

During the installation of halogen lamps do not touch the glass bulbs bare handed. Always use a cloth to handle the lamps during insertion and removal.

 

Do not install lamps with a higher wattage. They generate higher temperatures than which the device was designed for.

CLEANING AND MAINTENANCE

1. To reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.

2. Do not spill water or other liquids into or on to your unit.

3. During long periods of non-use, disconnect the unit’s main power.

4. It should be installed in a well-ventilated place, at a distance of 50 centimeters or more with the walls. At the same time, please check if the fan and ventilation holes are unobstructed.

 

The following points have to be considered during the inspection

1) All screws for installing the devices or parts of the device have to be tightly connected and must not be corroded.

2) There must not be any deformations on the housing, color lenses. Fixations and installations spots(ceiling, suspension, trussing).

3) Mechanically moved parts must not show any traces of wearing and must not rotate with unbalances.

4) The electric power supply cables must not show any damage, material fatigue or sediments. Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be removed.

 

CAUTION! Disconnect from mains before starting maintenance operation!

 

In order to make the lights in good condition and extend the life time, we suggest a regular cleaning to the lights.

1) Clean the inside and outside lens each week to avoid the weakness of the lights due to accumulation of dust.

2) Clean the fan each week.

3) To make sure the smooth gobo rotation, we suggest adding proper lube to the wheel each three month, avoiding the excessive lube splashes during the gobo rotating,

4) A detailed electric check by approved electrical engineer each three month, make sure that the circuit contacts are in good condition, prevent the poor contact of circuit from overheating.

 

We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or solvents.

 

There are no serviceable parts inside the device except for the lamp. Please refer to the instructions under “Installation instructions”.

 

Should you need any spare parts, please order genuine parts from your local dealer.

TECHNICAL PARAMETERS

POWER SUPPLIE

Input power:110-240V 50/60 Hz

 